PVC JACKETED MC ALUMINUM ARMOR XHHW-2 INNERS

Type MC cable shall be permitted as follows:
• Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings
• Acceptable for power, lighting, control, and signal circuits
• Utilized for indoor or outdoor applications
• Allowable in concealed or exposed systems
• Permitted in wet locations per NEC 330.10(A)(11)(a)
• Permitted for direct burial in the earth or embedded in concrete per NEC 330.12(2)(a)
• Acceptable for direct burial where identified for such use
• Allowable in assembly occupancies (NEC 518.4)
• Permissible in theaters, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)
• Permitted as aerial cable on a messenger
• Allowable installations in approved raceways and cable trays (NEC 392)
• Suitable for installation under raised floors for IT equipment (NEC 645.5)
• Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations
• Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems

 
09.12.2015
AC-HCF STEEL ARMOR THHN/THWN-2 INNERS

Encore’s Armored Cable is constructed with soft-drawn copper, Type THHN conductors. Each insulated conductor is individually wrapped with a moisture-resistant paper covering which has flame retardant properties. These conductors, including a green insulated grounding conductor, are cabled together to form the cable core. Interlocked steel armor is applied over the entire assembly. A 16 AWG solid aluminum bond wire is placed longitudinally underneath the armor and remains in contact with the armor throughout the entire length.

 
09.12.2015
AC-HCF ALUMINUM ARMOR THHN/THWN-2 INNERS

Encore’s Armored Cable is constructed with soft-drawn copper, Type THHN conductors. Each insulated conductor is individually wrapped with a moisture-resistant paper covering which has flame retardant properties. These conductors, including a green insulated grounding conductor, are cabled together to form the cable core. A 16 AWG solid aluminum bond wire is placed longitudinally underneath the armor and remains in contact with the armor throughout the entire length. Interlocked aluminum armor is applied over the entire assembly.

 
09.12.2015
AC STEEL ARMOR THHN/THWN-2 INNERS

Encore’s Armored Cable is constructed with soft-drawn copper, Type THHN conductors. Each insulated conductor is individually wrapped with a moisture-resistant paper covering which has flame retardant properties. These conductors, are cabled together to form the cable core. A 16 AWG solid aluminum bond wire is placed longitudinally underneath the armor and remains in contact with the armor throughout the entire length. Interlocked steel armor is applied over the entire assembly.

 
09.12.2015
AC ALUMINUM ARMOR THHN/THWN-2 INNERS

Encore’s Armored Cable is constructed with soft-drawn copper, Type THHN conductors. Each insulated conductor is individually wrapped with a moisture-resistant paper covering which has flame retardant properties. These conductors, are cabled together to form the cable core. A
16 AWG solid aluminum bond wire is placed longitudinally underneath the armor and remains in contact with the armor throughout the entire length. Interlocked aluminum armor is applied over the entire assembly.

 
09.12.2015
MC MUTLI-CIRCUIT ALUMINUM ARMOR THHN/THWN-2 INNERS

Available in sizes 12 AWG and 10 AWG with an insulated green ground conductor. Encore Wire Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90°C dry locations. All conductors are cabled together with a separator tape containing the identification print legend to form the cable core. Interlocked aluminum armor is applied over the entire assembly.

 
09.12.2015
MC MULTIPLE NEUTRAL ALUMINUM ARMOR THHN/THWN-2 INNERS

Available in sizes 12 AWG and 10 AWG with oversized neutral conductors or one neutral per phase and one insulated ground conductor. Encore Wire Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90°C dry locations. All conductors are cabled together with a separator tape containing the identification print legend to form the cable core. Interlocked aluminum armor is applied over the entire assembly.

 
09.12.2015
MC OVERSIZED NEUTRAL ALUMINUM ARMOR THHN/THWN-2 INNERS

Available in sizes 12 AWG and 10 AWG with an oversized neutral conductor and a green insulated ground conductor. Encore Wire Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90°C dry locations. All conductors are cabled together with a separator tape containing the identification print legend to form the cable core. Interlocked aluminum armor is applied over the entire assembly.

 
09.12.2015
MC ISOLATED GROUND ALUMINUM ARMOR THHN/THWN-2 INNERS

Available in sizes 12 AWG and 10 AWG with two (2) insulated ground conductors. Encore’s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90°C dry locations. The two grounding conductors are distinguished by color code: one (1) solid green, and one (1) solid green with yellow stripe. All conductors are cabled together with a separator tape containing the identification print legend to form the cable core. Interlocked aluminum armor is applied over the entire assembly.

 
09.12.2015
MC HCF-SG STEEL ARMOR THHN-THWN-2 INNERS

Available in sizes 12 AWG through 10 AWG. Encore’s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry. All conductors are individually wrapped with flame retardant colored protective paper with print legend and cabled together to form the cable core. Includes green ground same size as circuit conductors. The bare aluminum grounding/bonding conductor is located outside the paper wrap and is cabled with the insulated conductors and in constant contact with sheathing. Interlocked steel armor is applied over the entire assembly.

 
09.12.2015
MC HCF-SG ALUMINUM ARMOR THHN/THWN-2 INNERS

Available in sizes 12 AWG through 10 AWG. Encore’s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry. All conductors are individually wrapped with flame retardant colored protective paper with print legend and cabled together to form the cable core. Includes green ground same size as circuit conductors. The bare aluminum ground- ing/bonding conductor is located outside the paper wrap and is cabled with the insulated conductors and in constant contact with sheathing. Interlocked aluminum armor is applied over the entire assembly.

 
09.12.2015
MC STEEL ARMOR XHHW-2 INNERS

Available in sizes 14 AWG through 750 KCMIL, Encore’s Metal Clad Cable is constructed with soft-drawn copper, Type XHHW-2 conductors rated 90°C dry locations. Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor. Larger sizes are supplied with a bare ground conductor. All conductors are cabled together with separator tape containing the identification print legend to form the cable core. Interlocked galvanized steel armor is applied over the entire assembly.

 
09.12.2015
MC ALUMINUM ARMOR XHHW-2 INNERS

Available in sizes 14 AWG through 750 KCMIL, Encore’s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90°C dry locations. Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor. Larger sizes are supplied with a bare ground conductor. All conductors are cabled together with separator tape containing the identification print legend to form the cable core. Interlocked aluminum armor is applied over the entire assembly.

 
09.12.2015
MC STEEL ARMOR THHN/THWN-2 INNERS

Available in sizes 14 AWG through 750 KCMIL with a green insulated grounding conductor. Encore’s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90°C dry locations sizes 14 AWG through 1 AWG contain a green insulated ground. All conductors are cabled together with a separator tape, containing the identification print legend to form the cable core. Interlocked galvanized steel armor is applied over the entire assembly.

 
09.12.2015
MC ALUMINUM ARMOR THHN/THWN-2 INNERS

Available in sizes 14 AWG through 750 KCMIL, Encore’s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90°C dry locations. Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor. Larger sizes are supplied with a bare ground conductor. All conductors are cabled together with separator tape containing the identification print legend to form the cable core. Interlocked aluminum armor is applied over the entire assembly.

 
09.12.2015
TC POWER CABLE W/ GROUND, XHHW-2 INNERS

Primarily used for connecting power devices in an industrial environment. Suitable for installation in channels, ducts, raceways, cable trays, and conduits. Approved for direct burial in wet or dry locations and outdoors in cable trays where sunlight-resistant rating is required. Cables constructed and lisAtpedprfoxriampaptleications requiring TC-ER rating. Approved for Class I DivisOiounteIIrHJazcakredtoTuhsicLkocnaetsiosns.

 
09.12.2015
PVC JACKETED MC STEEL ARMOR THHN/THWN-2 INNERS 600V

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable is constructed with Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800;

ASTM B801; ASTM B836. Type THHN/THWN-2 conductors rated 90°C dry. Sizes 6 AWG through 750 KCMIL contain a bare aluminum ground wire. All conductors are cabled together with separator tape, which contain the identification print legend. Interlocked steel armor is applied. Overall sunlight-resistant, flame-retardant black PVC jacket, available in all colors.

 
09.12.2015
TC POWER & CONTROL W/O GROUND, XHHW-2 INNERS (14 AWG – 10 AWG)

Primarily used for connecting power devices in an industrial environment. Suitable for installation in channels, ducts, wireways, cable trays, and conduits. Approved for direct burial in wet or dry locations and outdoors in cable trays where sunlight-resistant rating is required. Cables constructed and listed for applications requiring TC-ER rating. Approved for Class I Division II Hazardous Locations.

 
09.12.2015
TC POWER CABLE W/O GROUND, XHHW-2 INNERS

Primarily used for connecting power devices in an industrial environment. Suitable for installation in channels, ducts, raceways, cable trays, and conduits. Approved for direct burial in wet or dry locations and outdoors in cable trays where sunlight-resistant rating is required. Cables constructed and lisAtpedprfoxriampaptleications requiring TC-ER rating. Approved for Class I DivisOiounteIIrHJazcakredtoTuhsicLkocnaetsiosns.

 
09.12.2015
TC POWER CABLE W/ BARE GROUND, XHHW-2 INNERS

Primarily used for connecting power devices in an industrial environment. Suitable for installation in channels, ducts, wireways, cable trays and conduits. Approved for direct burial in wet or dry locations and outdoors in cable trays where a sunlight-resistant rating is required. Cable constructed and listed for applications requiring TC-ER rating. Approved for Class I Division II Hazardous Locations.

 
09.12.2015
TC POWER CABLE W/ INSULATED GROUND, XHHW-2 INNERS (14 AWG – 10 AWG)

Primarily used for connecting power devices in an industrial environment. Suitable for installation in channels, ducts, raceways, cable trays, and conduits. Approved for direct burial in wet or dry locations and outdoors in cable trays where sunlight-resistant rating is required. Cables constructed and listed for applications requiring TC-ER rating. Approved for Class I Division II Hazardous Locations.

 
09.12.2015
Cyclone Barrel Pack

Available in 14 AWG through 10 AWG up to 7 conductors in THWN-2, XHHW- 2 and USE-2 constructions in both 120V and 277V color combinations; paralleled or cabled, eliminating the need for multiple reels.

 
09.12.2015
OVERHEAD SERVICE DROP AAAC 600V

Stranded, Concentric-Lay Aluminum Alloy 6201 Conductors per ASTM B399.

Suitable for overhead transmission and distribution applications that require rated strengths for 6201 alloy at a T81 temper. Encore’s AAAC overhead neutrals include Class AA for bare conductors usually used in overhead lines, and/or Class A for conductors to be covered with weather-resistant materials.

 
09.12.2015
TC POWER CABLE W/O GROUND, THHN/THWN-2 INNERS

Primarily used for connecting power devices in an industrial environment. Suitable for installation in channels, ducts, wireways, cable trays, and conduit. Approved for direct burial in wet or dry locations and outdoors in cable trays where sunlight-resistant rating is required. Cables constructed and listed for applications requiring TC-ER rating. Approved for Class I Division II Hazardous Locations.

 
09.12.2015
OVERHEAD SERVICE DROP ACSR 600V

Stranded, Concentric-Lay Aluminum 1350 Series Conductors with Steel Support Center Wire(s) per ASTM B232.

Suitable for overhead transmission and distribution applications that require rated strengths for steel support. Encore’s ACSR overhead neutrals include Class AA for bare conductors commonly used in overhead lines, and/or Class A for conductors to be covered with weather-resistant materials.

 
09.12.2015
TC POWER & CONTROL W/O GROUND, THHN/THWN-2 (14 AWG – 10 AWG)

Primarily used for connecting power devices in an industrial environment. Suitable for installation in channels, ducts, wireways, cable trays and conduits. Approved for direct burial in wet or dry locations and outdoors in cable trays where a sunlight-resistant rating is required. Cable constructed and listed for applications requiring TC-ER rating. Approved for Class I Division II Hazardous Locations.

 
09.12.2015
POWER CABLE WITHOUT GROUND, XHHW-2 INNERS

Primarily used for connect power devices in an industrial environment. Suitable for installation in channels, ducts, wireways, cable trays, and conduit. Approved for direct burial in wet or dry locations and outdoors in cable trays where sunlight-resistant rating is required. Cable constructed and listed for applications requiring type TC-ER rating. Approved for Class I Division II Hazardous Locations.

 
09.12.2015
The Reel Deal

See the difference with the Reel Deal with Encore’s compartmentalized wooden reel.

Available in reel sizes: 32″, 36″, 42″, and 48″ in THHN/THWN-2, XHHW-2 and USE-2.

 
09.12.2015
TC POWER CABLE W/ GROUND, THHN/THWN-2 INNERS

Primarily used for connecting power devices in an industrial environment. Suitable for installation in channels, ducts, wireways, cable trays and conduits. Approved for direct burial in wet or dry locations and outdoors in cable trays where a sunlight-resistant rating is required. Cable constructed and listed for applications requiring TC-ER rating. Approved for Class I Division II Hazardous Locations.

 
09.12.2015
POWER CABLE W/ GROUND, XHHW-2 INNERS

Primarily used for connect power devices in an industrial environment. Suitable for installation in channels, ducts, wireways, cable trays, and conduit. Approved for direct burial in wet or dry locations and outdoors in cable trays where sunlight-resistant rating is required. Cable constructed and listed for applications requiring type TC-ER rating. Approved for Class I Division II Hazardous Locations.

 
09.12.2015
The Reel Payoff

The industry’s only self-spinning wooden reel is available in reel sizes 24″, 30″, 32″, 36″, 42″ 48″ and in THHN/THWN-2, XHHW-2 or USE-2.

 
09.12.2015
TC POWER AND CONTROL W/ GROUND, THHN/THWN-2 INNERS (14 AWG – 10 AWG)

Primarily used for connecting power devices in an industrial environment. Suitable for installation in channels, ducts, wireways, cable trays and conduits. Approved for direct burial in wet or dry locations and outdoors in cable trays where a sunlight-resistant rating is required.

 
09.12.2015
POWER CABLE W/O GROUND, THHN/THWN-2 INNERS

Primarily used for connect power devices in an industrial environment. Suitable for installation in channels, ducts, wireways, cable trays, and conduit. Approved for direct burial in wet or dry locations and outdoors in cable trays where sunlight-resistant rating is required. Cable constructed and listed for applications requiring type TC-ER rating. Approved for Class I Division II Hazardous Locations.

 
09.12.2015
THE PULLPRO

Budget, safety and agility take priority on any job site, so we developed a product that weighs less than 30lbs, requires no additional tools and fits into any small space for storage. The PullPro’s case is manufactured from durable material that can withstand nearly any drop, but in the event you’d like to drop it from extreme heights, don’t worry, PullPro’s technology allows for a seamless wire pull with or without the case. http://www.encorewire.com/pullpro/

 
25.08.2015
iTOOL WINDOW CRIMP™ WITH SURE GRIP

For use on Copper and Aluminum products, sizes 8 AWG through 1000 Kcmil.

 
30.12.2014
MC-LED™ LIGHTING CABLE THHN/THWN-2 INNERS

MC-LED (Type MC-PCS) cable is designed for use with LED and Fluorescent dimming systems and smart building technology that offers optimal control over the building’s lighting systems. MC-LED may be surface mounted, fished and/or embedded in plaster in normally dry locations. MC-LED eliminates the need to install a separate low-voltage cable and traditional lighting/power MC Cable to a single luminaire. UL Classified for 1, 2 and 3 hour through penetrations (Fire-Stop). Meets acceptable uses in accordance with NEC 250.118(10)(a), 300.22(C), 392, 396, 330, 501, 502, 503, 504, 505, 518, 520, 530, 645 and 725.

 
10.06.2013
USE-2/RHH/RHW-2 600V

Type USE-2 or RHH or RHW-2 cables with Aluminum Alloy 8000 Series conductors are suitable for use in conduit and raceways installed underground in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90°C.

 

 
26.02.2013
MC STEEL ARMOR THHN/THWN-2 INNERS 600V

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable conductors are constructed with Compact Stranded Aluminum Alloy 8000 Series per ASTM B800, B801,and B836. Type THHN/THWN-2 conductors rated 90°C dry. Sizes 6 AWG through 750 KCMIL contain a bare aluminum ground wire. All conductors are cabled together with separatortape, containing the identification print legend. Interlocked steel armor is applied over the assembly.

 
26.02.2013
MC STEEL ARMOR XHHW-2 INNERS 600V

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable conductors are constructed with Compact Stranded Conductors Aluminum Alloy 8000Series per ASTM B800, B801, and B836. Type XHHW-2 conductors rated 90°C dry. Sizes 6 AWG through 750 KCMIL contain a bare aluminum ground wire. Allconductors are cabled together with separator tape, containing the identification print legend. Interlocked steel armor is applied over the assembly.

 
26.02.2013
UNDERGROUND DISTRIBUTION SINGLE-RATED CABLE 1350 SERIES 600V

Single-rated XLPE insulated cables for underground service entrance applications not exceeding 600 volts. May be used as single-rated type USE-2 for NEC® applications as well as non-NEC applications including direct burial, or for installation in ducts or conduits.

 
26.02.2013
UNDERGROUND DISTRIBUTION TRIPLE-RATED CABLE AA-8000 SERIES 600V

Triple-rated USE-2/RHH/RHW-2 conductors are suitable for underground service entrance applications and additionally for applications in raceways for general purpose lighting and power circuits. Triple-rated conductors are additionally suitable for installation on both sides of the service point, and when the service point is located inside building envelope.

 
05.02.2013
SOOW Cord

Industrial and processing equipment, cranes and hoists, track systems, tools, construction equipment, motors and associated machinery, garage portable lights, battery charger and equipment exposed to oils, solvents, flame, moisture and other electrical equipment.

 
05.02.2013
Thermostat Cable

• Wiring of thermostat controls, heating and air conditioning equipment, doorbells, as well as other low voltage applications
• Sunlight-resistant (except plenum)

 
05.02.2013
Speaker Cable

Direct Burial Sound Audio Cable

 
05.02.2013
SJOOW Cord

Industrial and processing equipment, cranes and hoists, track systems, tools, construction equipment, motors and associated machinery, garage portable lights, battery charger and equipment exposed to oils, solvents, flame, moisture and other electrical equipment

 
05.02.2013
NM Flexible Conduit

A general-purpose, nonmetallic liquid-tight conduit offers excellent protection to wiring from abrasion, sunlight, mild acids, alkaline, and oils. Often used for air conditioning hook-ups and other outdoor applications.

 
05.02.2013
LA Flexible Conduit
 
05.02.2013
EF Flexible Conduit
 
05.02.2013
Coaxial Cable

Common for broadband applications including CATV & HDTV.

 
05.02.2013
24 AWG 4 Pair Category 5E Cable – Riser-Rated

• Gigabit Ethernet, Bi-Directional Transmissions, 100 BaseT, 1000 BaseT, Broad Band Video, Fast Ethernet, 155 Mbs ATM, TI, ISDN, 622 Mbps ATM
• Commercial/Residential Phone/Fax/Internet systems

 
05.02.2013
24 AWG 4 Pair Category 5E Cable – Plenum-Rated

• Gigabit Ethernet
• 100 Base-T, 1000 BaseT
• 155 Mbps ATM
• 622 Mbps ATM
• Broad Band Video
• Fast Ethernet
• Bi-Directional Transmissions
• T1, ISDN

 
05.02.2013
Category 3 Cable

• 4 Mbps Token Ringä (IEEE 802.5)
• 10Mbps 10 Base-T ETHERNETTM (IEEE 802.3)
• Residential and Office Phone/Fax/Internet Systems

 
05.02.2013
BR Flexible Conduit

This conduit is intended for installation as a metal raceway for wires and cable in accordance with the NEC (ANSI/NFPA-70) Article 348.
• Suitable as an equipment grounding conductor (Section 250.118(5))
• Wiring in elevators, hoist ways and escalators (Section 620.21)
• Limit on use of 3/8 inch trade size (Section 348.20)
• Raceway connection to motors (Section 430.223)
• Cranes and hoists (Section 610.11)
• Manufactured Wiring Systems – (Section 604.6(a))
• Suitable for use with listed connectors intended for FMC (Flexible Metal Conduit)
• Flexible metal conduit is also permitted for use on industrial machinery (ANSI//NFPA-79) (Section 14.5.4)

 
05.02.2013
ABR Flexible Conduit

This non-jacketed flexible aluminum conduit has many universal wiring applications. It is often referred to as “Greenfield” or “Reduced Wall Flex”.

 
06.01.2013
PVC JACKETED MC ALUMINUM ARMOR THHN/THWN-2 INNERS 600V

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable conductors are constructed with Compact Stranded Aluminum Alloy 8000 Series per ASTM B800, B801, and B836. Permitted use for service, feeders, and branch circuits in industrial, commercial, and multi-residential buildings.

 

 
06.01.2013
POWER CABLE W/ GROUND, THHN/THWN-2 INNERS

Primarily used for connect power devices in an industrial environment. Suitable for installation in channels, ducts, wireways, cable trays, and conduit. Approved for direct burial in wet or dry locations and outdoors in cable trays where sunlight-resistant rating is required. Cable constructed and listed for applications requiring type TC-ER rating. Approved for Class I Division II Hazardous Locations.

 

 
06.01.2013
SE STYLE U, 600V

For above ground electrical service use from the electric utility power service point to the meter or service entrance panel. Under special conditions as permitted, the NEC Type SE Style U can be used for interior wiring as branch circuits to ranges, ovens, cooking units, or clothes dryers.

 
06.01.2013
SE STYLE R, 600V

For above ground electrical service use from the electric utility power service point to the meter or service entrance panel. Under special conditions as permitted, the NEC Type SE Style R can be used for interior wiring as branch circuits to ranges, ovens, cooking units, or clothes dryers

 
06.01.2013
MOBILE HOME FEEDER 600V

Quadraplexed type USE-2/RHH/RHW-2 with Compact Stranded Aluminum Alloy 8000 Series conductors per ASTM B800, B801, and B836. Suitable for electrical connections in mobile homes for permanent wiring according to the 2008 NEC®.

 
06.01.2013
PVC JACKETED MC STEEL ARMOR XHHW-2 INNERS 600V

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable is constructed with Compact Stranded Conductors Aluminum Alloy 8000 Series per ASTM B800, B801, and B836. Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings.

 

 
06.01.2013
MC ALUMINUM ARMOR XHHW-2 INNERS 600V

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable conductors are constructed with Compact Stranded Conductors Aluminum Alloy 8000 Series per ASTM B800, B801, and B836. Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings.

 

 
06.01.2013
MC ALUMINUM ARMOR THHN/THWN-2 INNERS 600V

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable conductors are constructed with Compact Stranded Aluminum Alloy 8000 Series per ASTM B800, B801, and B836. Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings.

 

 
06.01.2013
PVC JACKETED MC ALUMINUM ARMOR XHHW-2 INNERS 600V

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable is constructed with Compact Stranded Conductors Aluminum Alloy 8000 Series per ASTM B800, B801, and B836. Type XHHW-2 conductors rated 90°C dry. Permitted use for service, feeders and branch circuits in industrial, commercial, and multi-residential buildings.

 

 
06.01.2013
OVERHEAD SERVICE DROP AAC 600V

Stranded, Concentric-Lay Aluminum Conductors, 1350 Series Alloy per ASTM B231.

Suitable for overhead transmission and distribution applications that do not require the rated strength of ACSR type neutrals. Encore’s AAC overhead neutrals include Class AA for bare conductors usually used in overhead lines, and/or Class A for conductors to be covered with weather-resistant materials. Class A also for bare conductors where greater flexibility is required.

 
06.01.2013
XHHW-2/RW90 SUPERSLICK ELITE® 600V

Type XHHW-2 building wire is intended for general purpose applications utilized in conduit or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the National Electrical Code (NEC).

 

 
06.01.2013
THHN/THWN-2/T90 SUPERSLICK ELITE® 600V

Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code® (NEC®). Type THHN-THWN-2 is permitted for new construction or rewiring for 600 volt applications.

 

 
06.01.2013
PHOTOVOLTAIC/RHH/RHW-2 600V AND 1000V/2000V

Type Photovoltaic building wire is suitable for outdoor rooftop applications without conduit and for use in conduits and raceways installed underground in conduit, in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90°C.

 

 
07.06.2011
TC CONTROL OR INSTRUMENTATION SHIELDED (18 AWG – 10 AWG)

Primarily used for connecting power devices in an industrial environment. Suitable for installation in channels, ducts, wireways, cable trays, and conduits. Approved for direct burial in wet or dry locations and outdoors in cable trays where sunlight-resistant rating is required.

 
07.06.2011
MC-SG (SMARTGROUND™) STEEL ARMOR THHN/THWN-2 INNERS

Available in sizes 14 AWG through 10 AWG. Encore’s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/ THWN-2 conductors rated 90°C dry. All conductors are individually wrapped with flame retardant colored protective paper with print legend and cabled together to form the cable core. The bare aluminum grounding/bonding conductor is located outside the paper wrap and is cabled with the insulated conductors and in constant contact with sheathing. Interlocked steel armor is applied over the entire assembly.

 
07.06.2011
MC-SG (SMARTGROUND™) ALUMINUM ARMOR THHN/THWN-2 INNERS

Available in sizes 14 AWG through 10 AWG. Encore’s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/ THWN-2 conductors rated 90°C dry. All conductors are individually wrapped with flame retardant colored protective paper with print legend and cabled together to form the cable core. The bare aluminum grounding/bonding conductor is located outside the paper wrap and is cabled with the insulated conductors and in constant contact with sheathing. Interlocked aluminum armor is applied over the entire assembly.

 
07.06.2011
MC MULTIPLE NEUTRAL STEEL ARMOR THHN/THWN-2 INNERS

Available in sizes 12 AWG and 10 AWG with oversized neutral conductors or one neutral per phase and one insulated ground conductor. Encore Wire Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90°C dry locations. All conductors are cabled together with a separator tape containing the identification print legend to form the cable core. Interlocked steel armor is applied over the entire assembly.

 
07.06.2011
MC-FPLP PLENUM RATED LIMITED POWER TYPE FIRE ALARM & CONTROL CABLE

Available in sizes 18 AWG through 12 AWG. Encore’s Fire Alarm and Control Cable is constructed with soft-drawn copper and classified as type TFN (Sizes 18 & 16 AWG) conductors. Sizes with 14 AWG through 12 AWG conductors are classified as type THHN/THWN-2 conductors. Each Fire Alarm and Control Cable contains a green insulated grounding conductor. All conductors are cabled together with separator tape containing the identification print legend to form the cable core. Interlocked aluminum or galvanized steel armor is applied over the entire assembly.

 
07.06.2011
XHHW-2 / RW90 SUPERSLICK ELITE®

Type XHHW-2/RW90 building wire is intended for general purpose applications utilized in conduit, underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the National Electrical Code (NEC).

 
07.06.2011
BARREL PACKS XHHW-2 / RW90

Type XHHW-2/RW90 building wire is intended for general purpose applications utilized in conduit, underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the National Electrical Code (NEC).

 
07.06.2011
USE-2 / RHH / RHW-2

Type USE-2 or RHH or RHW-2 copper conductors are suitable for use in conduit and raceways installed underground in conduit, wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90˚C.

 
07.06.2011
TW-#8 SOLID GREEN

Type TW is suitable for use in conduit or other recognized raceways for services, feeders, and branch-circuit wiring. Suitable for use in wet or dry locations where temperatures do not exceed 75°C.

 
07.06.2011
TRACER WIRE 30V AND 600V

Available in sizes 14AWG through 8AWG. 30 volt styles have a 30 MIL insulation wall; 600 volt styles have a 45 MIL insulation wall. Solid or stranded uncoated copper conductors. Suitable for direct burial in wet or dry locations. High Molecular Weight Polyethylene (HMWPE) insulation has excellent moisture, chemical, oil, crush, and abrasion resistance. Rated 90 ̊C wet or dry. Carries -40 ̊C rating. Colors in accordance with the American Public Works Administration Uniform Color Code: yellow for gaseous materials; red for electrical lines; orange for communications; blue for potable water; green for sewers and drain lines. Other colors available upon request.

 
07.06.2011
THW-2

Type THW-2 conductor is intended for general purpose applications utilized in conduit or other raceways for services, feeders, and branch-circuit wiring as specified in the National Electric Code (NEC). May be used in wet or dry locations at temperatures not to exceed 90˚C. Type THW-2 is permitted for 600 volt applications.

 
07.06.2011
THHN / MTW / THWN-2 / T90 SUPERSLICK ELITE®

Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications.

 
07.06.2011
BARREL PACKS THHN / MTW / THWN-2 / T90

Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications.

 
07.06.2011
TFFN / TFN / TEWN

Type TFFN (stranded) or TFN (solid) conductors are primarily used as fixture wire as defined by the National Electrical Code (NEC) at temperatures not to exceed 90°C in dry locations. For applications requiring Type MTW, the conductor is permitted for use in dry locations at 90°C or not to exceed 60°C in wet locations or where exposed to oils or coolants.

All sizes are rated gasoline and oil-resistant II.

 
07.06.2011
PHOTOVOLTAIC 600V AND 1000V/2000V

Type Photovoltaic copper conductors are suitable for outdoor rooftop applications without conduit and for use in conduits and raceways installed underground in conduit in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90ºC.

 
07.06.2011
MTW / AWM / TEW MACHINE TOOL & APPLIANCE WIRE

Type MTW or TEW conductors are primarily used in control cabinets, in machine tool applications, and in appliance wiring applications at temperatures -25°C to 105°C. For use in accordance with the National Electrical Code (NEC) and NFPA Standard 79. Voltage rating for all applications is 600 volts.

 
07.06.2011
PVC JACKETED MC STEEL ARMOR XHHW-2 INNERS

Available in sizes 14 AWG through 750 KCMIL, Encore’s Metal Clad Cable is constructed with soft-drawn copper. Type XHHW-2 conductors rated for wet or dry locations at temperatures not to exceed 90oC. Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor. All conductors are cabled together with separator tape containing the identification print legend to form the cable core. Interlocked aluminum armor is applied over the entire assembly. A flame retardant sunlight resistant black PVC jacket applied over the armor. Additional jacket colors are available upon request.

 
07.06.2011
PVC JACKETED MC ALUMINUM ARMOR THHN/THWN-2 INNERS

Available in sizes 14 AWG through 750 KCMIL, Encore’s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90°C dry or wet locations.

Sizes 14AWG through 1AWG contain a green insulated grounding conductor. Larger sizes are supplied with a bare ground conductor.

All conductors are cabled together with separator tape containing the identification print legend to form the cable core. Interlocked aluminum armor is applied over the entire assembly.

A flame retardant sunlight resistant black PVC jacket is applied over the armor. Additional jacket colors are available upon request.

 
07.06.2011
SOFT-DRAWN BARE

Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding.

 
07.06.2011
BARREL PACKS SOFT-DRAWN BARE CONDUCTORS

Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding.

 
07.06.2011
UF-B

Type UF-B (Underground Feeder Cable) has a broad range of usage as defined in Article 340 of the National Electrical Code (NEC). Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial. Type UF-B may also be used in applications permitted for Type NM-C construction as specified in Article 334.10 B of the NEC. Maximum voltage rating for UF-B is 600 volts.

 
07.06.2011
SE-STYLE R 600V

For above ground electrical service use from the electric utility power service point to the meter or service entrance panel. Under special conditions as permitted, the NEC Type SE Style R can be used for interior wiring as branch circuit to ranges, ovens, cooking units, or clothes dryers. Type SE Style R is manufactured in accordance with Article 338 of the NEC and the requirements of Underwriters Laboratories Standard 854 and is approved for installation in accordance with Article 230 of the NEC and has a rating of 600 volts.

 
07.06.2011
SE-STYLE U 600V

For above ground electrical service use from the electric utility power service point to the meter or service entrance panel. Under special conditions as permitted, the NEC Type SE Style U can be used for interior wiring as branch circuits to ranges, ovens, cooking units, or clothes dryers. Type SE Style U is manufactured in accordance with Article 338 of the NEC and also the requirements of Underwriters Laboratories Standard 854 and is approved for installation in accordance with Article 230 of the NEC and has a rating of 600 volts.

 
06.06.2011
NM-B SuperSlick Elite®

Type NM-B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC). Type NM-B cable is commonly used for residential fixtures, switches, and loads rated for at least 90°C. Type NM-B ampacity limitation shall be in accordance with the 60°C conductor temperature rating, as specified in the National Electrical Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations. Type NM-B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness.