Archive

 
13.01.2014
MC-COPPER CONDUCTOR – ALUMINUM ARMOR PVC JACKET XHHW-2 INNERS
  • Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
 
10.06.2013
USE-2/RHH/RHW-2 ® – 600V

Type USE-2 or RHH or RHW-2 cables with Aluminum Alloy 8000 Series conductors are suitable for use in conduit and raceways installed underground in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90°C.

 

 
26.02.2013
MC – STEEL ARMOR – 600V THHN/THWN-2 INNERS

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable conductors are constructed with Compact Stranded Aluminum Alloy 8000 Series per ASTM B800, B801,and B836. Type THHN/THWN-2 conductors rated 90°C dry. Sizes 6 AWG through 750 KCMIL contain a bare aluminum ground wire. All conductors are cabled together with separatortape, containing the identification print legend. Interlocked steel armor is applied over the assembly.

 
26.02.2013
MC – STEEL ARMOR – 600V XHHW-2 INNERS

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable conductors are constructed with Compact Stranded Conductors Aluminum Alloy 8000Series per ASTM B800, B801, and B836. Type XHHW-2 conductors rated 90°C dry. Sizes 6 AWG through 750 KCMIL contain a bare aluminum ground wire. Allconductors are cabled together with separator tape, containing the identification print legend. Interlocked steel armor is applied over the assembly.

 
26.02.2013
UNDERGROUND DISTRIBUTION – SINGLE RATED CABLE – 600V

Single-rated XLPE insulated cables for underground service entrance applications not exceeding 600 volts. May be used as single-rated type USE-2 for NEC® applications as well as non-NEC applications including direct burial, or for installation in ducts or conduits.

 
26.02.2013
UNDERGROUND DISTRIBUTION – TRIPLE RATED CABLE – 600V

Triple-rated USE-2/RHH/RHW-2 conductors are suitable for underground service entrance applications and additionally for applications in raceways for general purpose lighting and power circuits. Triple-rated conductors are additionally suitable for installation on both sides of the service point, and when the service point is located inside building envelope.

 
05.02.2013
SOOW Cord
 
05.02.2013
Thermostat Cable
 
05.02.2013
Speaker Cable

Direct Burial Sound Audio Cable

 
05.02.2013
SJOOW Cord
 
05.02.2013
Riser Electronic CMR/CL2R/CL3R

Unshielded, Non-Plenum

 
05.02.2013
NM Flexible Conduit
 
05.02.2013
LA Flexible Conduit
 
05.02.2013
Fire Alarm Multi-Conductor Cable

Unshielded, Riser-Rated

 
05.02.2013
Fire Alarm Multi-Conductor Cable

Unshielded, Plenum Type FPLP

 
05.02.2013
Fire Alarm Multi-Conductor Cable

Overall Shield, Riser-Rated

 
05.02.2013
Fire Alarm Multi-Conductor Cable

Overall Shield, Plenum Type FPLP

 
05.02.2013
EF Flexible Conduit
 
05.02.2013
Coaxial Cable

18 AWG Copper-Clad Steel

 
05.02.2013
CMR Multi-Conductor Electronic Wire

Unshielded, Riser-Rated

 
05.02.2013
CMR Multi-Conductor Electronic Wire

Overall Shield, Riser-Rated

 
05.02.2013
CMP Plenum Multi-Conductor Electronic Wire

Unshielded, Plenum-Rated

 
05.02.2013
CMP Plenum Multi-Conductor Electronic Wire

Overall Shielded, Plenum-Rated

 
05.02.2013
24 AWG 4 Pair Category 5E Cable

Riser-Rated

 
05.02.2013
24 AWG 4 Pair Category 5E Cable

Plenum-Rated

 
05.02.2013
Category 3 Cable

Telephone Wire

 
05.02.2013
BR Flexible Conduit
 
 
06.01.2013
MC – ALUMINUM ARMOR – PVC JACKET – 600V THHN/THWN-2 INNERS

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable conductors are constructed with Compact Stranded Aluminum Alloy 8000 Series per ASTM B800, B801, and B836. Permitted use for service, feeders, and branch circuits in industrial, commercial, and multi-residential buildings.

 

 
06.01.2013
POWER CABLE – 600V

Primarily used for connect power devices in an industrial environment. Suitable for installation in channels, ducts, wireways, cable trays and conduit. Approved for direct burial in wet or dry locations and outdoors in cable trays where sunlight-resistant rating is required.

 

 
06.01.2013
SEU – 600V

For above ground electrical service use from the electric utility power service point to the meter or service entrance panel. Under special conditions as permitted, the NEC Type SE Style U can be used for interior wiring as branch circuits to ranges, ovens, cooking units, or clothes dryers.

 
06.01.2013
SER – 600V

For above ground electrical service use from the electric utility power service point to the meter or service entrance panel. Under special conditions as permitted, the NEC Type SE Style R can be used for interior wiring as branch circuits to ranges, ovens, cooking units, or clothes dryers

 
06.01.2013
MOBILE HOME FEEDER – 600V

Quadraplexed type USE-2/RHH/RHW-2 with Compact Stranded Aluminum Alloy 8000 Series conductors per ASTM B800, B801, and B836. Suitable for electrical connections in mobile homes for permanent wiring according to the 2008 NEC®.

 
06.01.2013
MC – STEEL ARMOR – PVC JACKET – 600V XHHW-2 INNERS

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable is constructed with Compact Stranded Conductors Aluminum Alloy 8000 Series per ASTM B800, B801, and B836. Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings.

 

 
06.01.2013
MC – ALUMINUM ARMOR – 600V XHHW-2 INNERS

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable conductors are constructed with Compact Stranded Conductors Aluminum Alloy 8000 Series per ASTM B800, B801, and B836. Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings.

 

 
06.01.2013
MC – ALUMINUM ARMOR – 600V THHN/THWN-2 INNERS

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable conductors are constructed with Compact Stranded Aluminum Alloy 8000 Series per ASTM B800, B801, and B836. Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings.

 

 
06.01.2013
MC – ALUMINUM ARMOR – PVC JACKET – 600V XHHW-2 INNERS

Available in sizes 6 AWG through 750 KCMIL, Encore Wire’s Metal-Clad Cable is constructed with Compact Stranded Conductors Aluminum Alloy 8000 Series per ASTM B800, B801, and B836. Type XHHW-2 conductors rated 90°C dry. Permitted use for service, feeders and branch circuits in industrial, commercial, and multi-residential buildings.

 

 
06.01.2013
OVERHEAD SERVICE DROP 600V

Overhead service drop cable is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90°C.

 
06.01.2013
XHHW-2/RW90 – SSE® – 600V

Type XHHW-2 building wire is intended for general purpose applications utilized in conduit or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the National Electrical Code (NEC).

 

 
06.01.2013
THHN/THWN-2/T90 – SSE® – 600V

Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code® (NEC®). Type THHN-THWN-2 is permitted for new construction or rewiring for 600 volt applications.

 

 
06.01.2013
PHOTOVOLTAIC – 600V & 1000V/2000V

Type Photovoltaic building wire is suitable for outdoor rooftop applications without conduit and for use in conduits and raceways installed underground in conduit, in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90°C.

 

 
30.07.2012
Rectorseal ® Single-Use Wire Grabber

For use on THHN and XHHW copper and aluminum wire only.

 
24.06.2011
SMARTCOLOR ID® MC-COPPER CONDUCTOR MULTIPLE NEUTRAL ALUMINUM ARMOR THHN/THWN-2 INNERS

Type MC cable shall be permitted as follows:

  • Power system designs used to supply power to nonlinear loads may allow for the possibility of high harmonics
  • Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings
  • Acceptable for power, lighting, control, and signal circuits
  • Allowable in concealed or exposed systems
 
24.06.2011
SMARTCOLOR ID® MC-COPPER CONDUCTOR MULTIPLE NEUTRAL ALUMINUM ARMOR THHN/THWN-2 INNERS

Type MC cable shall be permitted as follows:

  • Power system designs used to supply power to nonlinear loads may allow for the possibility of high harmonics
  • Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings
  • Acceptable for power, lighting, control, and signal circuits
  • Allowable in concealed or exposed systems
 
07.06.2011
TC-POWER & CONTROL CABLE

Primarily used for connecting power devices in an industrial environment. Suitable for installation in channels, ducts, wireways, cable trays and conduits. Approved for direct burial in wet or dry locations and outdoors in cable trays where a sunlight-resistant rating is required.

 
07.06.2011
TC-CONTROL OR INSTRUMENTATION-SHIELDED

Primarily used for connecting power devices in an industrial environment. Suitable for installation in channels, ducts, wireways, cable trays, and conduits. Approved for direct burial in wet or dry locations and outdoors in cable trays where sunlight-resistant rating is required.

 
07.06.2011
SMARTCOLOR ID® MC-COPPER CONDUCTOR STEEL ARMOR/XHHW-2 INNERS

Type MC cable shall be permitted as follows:

  • Permitted use for service power and feeder distribution in industrial, commercial, and multi-residential buildings
  • Acceptable for power, lighting, control, and signal circuits
  • Allowable in concealed or exposed systems
 
07.06.2011
SMARTCOLOR ID® MC-COPPER CONDUCTOR-STEEL ARMOR/THHN INNERS

Type MC cable shall be permitted as follows:

Permitted use for services, feeders, and branch circuits in ndustrial, commercial, and multi-residential buildings
Acceptable for power, lighting, control, and signal circuits (NEC 300.22(C))

 
07.06.2011
SMARTCOLOR ID® MC-COPPER CONDUCTOR-ALUMINUM ARMOR

Type MC cable shall be permitted as follows:

Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings
Acceptable for power, lighting, control, and signal circuits
Allowable in concealed or exposed systems

 
07.06.2011
MC-SG (SMARTGROUNDTM) COPPER CONDUCTOR STEEL ARMOR

Type MC cable shall be permitted as follows:

  • Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings
  • Acceptable for power, lighting, control, and signal circuits (NEC 300.22(C))
 
07.06.2011
MC-SG (SMARTGROUNDTM) COPPER CONDUCTOR ALUMINUM ARMOR

Type MC cable shall be permitted as follows:

  • Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings
  • Acceptable for power, lighting, control, and signal circuits (NEC 300.22(C))
 
07.06.2011
SMARTCOLOR ID® MC-COPPER CONDUCTOR OVERSIZED NEUTRAL AlUMINUM ARMOR THHN/THWN-2 INNERS

Type MC cable shall be permitted as follows:

  • Power system designs used to supply power to nonlinear loads may allow for the possibility of high harmonics
  • Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings
  • Acceptable for power, lighting, control, and signal circuits
  • Allowable in concealed or exposed systems
 
07.06.2011
SMARTCOLOR ID® MC-COPPER CONDUCTOR-MULTI-CIRCUIT-ALUMINUM ARMOR THHN/THWN-2 INNERS

Type MC cable shall be permitted as follows:

  • Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings
  • Acceptable for power, lighting, control, and signal circuits
  • Allowable in concealed or exposed systems
 
07.06.2011
SMARTCOLOR ID® MC-COPPER CONDUCTOR-MULTIPLE NEUTRAL-STEEL ARMOR THHN/THWN-2 INNERS

Type MC cable shall be permitted as follows:

  • Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings
  • Acceptable for power, lighting, control, and signal circuits
  • Allowable in concealed or exposed systems
 
07.06.2011
SMARTCOLOR ID® MC-COPPER CONDUCTOR ISOLATED GROUND ALUMINUM ARMOR THHN/THWN-2 INNERS

Type MC cable shall be permitted as follows:

  • Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings
  • Acceptable for power, lighting, control, and signal circuits
  • Allowable in concealed or exposed systems
 
07.06.2011
MC HCF – SG (SMARTGROUNDTM) COPPER CONDUCTOR
  • Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
 
07.06.2011
MC-FPLP PLENUM RATED LIMITED POWER TYPE FIRE ALARM AND CONTROL CABLE
  • Permitted use for Non-Power Limited Fire Alarm (NPLFA) and Power Limited Fire Alarm Circuits (PLFA) including alarms, horns, detecting devices, and overall signaling devices
  • Acceptable for power, lighting, control, and signal circuits
 
07.06.2011
SMARTCOLOR ID® AC-HCF COPPER CONDUCTOR ALUMINUM ARMOR
  • Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
 
07.06.2011
SMARTCOLOR ID® AC-COPPER CONDUCTOR-STEEL ARMOR/THHN INNERS
  • Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings
  • Acceptable for power, lighting, control, and signal circuits
  • Utilized for indoor or outdoor applications and allowable in concealed or exposed systems
 
07.06.2011
SMARTCOLOR ID® AC-COPPER CONDUCTOR-Aluminum Armor/THHN INNERS
  • Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings
  • Acceptable for power, lighting, control, and signal circuits
  • Allowable in concealed or exposed systems
 
07.06.2011
XHHW-2 / RW90 COPPER CONDUCTOR SUPERSLICK ELITE®

Type XHHW-2/RW90 building wire is intended for general purpose applications utilized in conduit, underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the National Electrical Code (NEC).

 
07.06.2011
BARREL PACKS XHHW-2 / RW90 COPPER CONDUCTOR

Type XHHW-2/RW90 building wire is intended for general purpose applications utilized in conduit, underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the National Electrical Code (NEC).

 
07.06.2011
USE-2/RHH/RHW-2 COPPER CONDUCTOR

Type USE-2 or RHH or RHW-2 copper conductors are suitable for use in conduit and raceways installed underground in conduit, wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90˚C.

 
07.06.2011
TW-#8 SOLID GREEN

Type TW is suitable for use in conduit or other recognized raceways for services, feeders, and branch-circuit wiring. Suitable for use in wet or dry locations where temperatures do not exceed 75°C.

 
07.06.2011
TRACER WIRE COPPER CONDUCTOR / 30 VOLT & 600 VOLT

Listed for 30V or 600V. Primarily used in the detection of underground piping and other underground utility installations.

 
07.06.2011
THW-2 COPPER CONDUCTOR

Type THW-2 conductor is intended for general purpose applications utilized in conduit or other raceways for services, feeders, and branch-circuit wiring as specified in the National Electric Code (NEC). May be used in wet or dry locations at temperatures not to exceed 90˚C. Type THW-2 is permitted for 600 volt applications.

 
07.06.2011
THHN/MTW/THWN-2/T90 COPPER CONDUCTOR SUPERSLICK ELITE®

Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications.

 
07.06.2011
BARREL PACKS THHN / MTW / THWN-2 / T90 COPPER CONDUCTOR

Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications.

 
07.06.2011
TFFN / TFn / TEWN COPPER CONDUCTOR

Type TFFN (stranded) or TFN (solid) conductors are primarily used as fixture wire as defined by the National Electrical Code (NEC) at temperatures not to exceed 90°C in dry locations. For applications requiring Type MTW, the conductor is permitted for use in dry locations at 90°C or not to exceed 60°C in wet locations or where exposed to oils or coolants.

 
07.06.2011
PHOTOVOLTAIC COPPER CONDUCTOR 600V AND 1000V/2000V

Type Photovoltaic copper conductors are suitable for outdoor rooftop applications without conduit and for use in conduits and raceways installed underground in conduit in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90ºC.

 
07.06.2011
MTW / AWM / TEW MACHINE TOOL & APPLIANCE WIRE

Type MTW or TEW conductors are primarily used in control cabinets, in machine tool applications, and in appliance wiring applications at temperatures -25°C to 105°C. For use in accordance with the National Electrical Code (NEC) and NFPA Standard 79. Voltage rating for all applications is 600 volts.

 
07.06.2011
MC-COPPER CONDUCTOR-Steel ARMOR PVC JACKET XHHW-2 INNERS

Applications: Type MC cable shall be permitted as follows:

  • Permitted use for services, feeders, and branch circuits in industrial,
    commercial, and multi-residential buildings
  • Acceptable for power, lighting, control, and signal circuits
 
07.06.2011
MC-COPPER CONDUCTOR – ALUMINUM ARMOR PVC JACKET THHN-2 INNERS

Type MC cable shall be permitted as follows:

  • Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings
  • Acceptable for power, lighting, control, and signal circuits
 
07.06.2011
SOFT-DRAWN BARE CONDUCTORS

Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding.

 
07.06.2011
BARREL PACKS SOFT-DRAWN BARE CONDUCTORS

Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding.

 
07.06.2011
UF-B COPPER CONDUCTOR

Type UF-B (Underground Feeder Cable) has a broad range of usage as defined in Article 340 of the National Electrical Code (NEC). Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial. Type UF-B may also be used in applications permitted for Type NM-C construction as specified in Article 334.10 B of the NEC. Maximum voltage rating for UF-B is 600 volts.

 
07.06.2011
COPPER TYPE SE-STYLE R 600-VOLT CONDUCTOR

For above ground electrical service use from the electric utility power service point to the meter or service entrance panel. Under special conditions as permitted, the NEC Type SE Style R can be used for interior wiring as branch circuit to ranges, ovens, cooking units, or clothes dryers. Type SE Style R is manufactured in accordance with Article 338 of the NEC and the requirements of Underwriters Laboratories Standard 854 and is approved for installation in accordance with Article 230 of the NEC and has a rating of 600 volts.

 
07.06.2011
COPPER TYPE SE-STYLE U 600-VOLT CONDUCTOR

For above ground electrical service use from the electric utility power service point to the meter or service entrance panel. Under special conditions as permitted, the NEC Type SE Style U can be used for interior wiring as branch circuits to ranges, ovens, cooking units, or clothes dryers. Type SE Style U is manufactured in accordance with Article 338 of the NEC and also the requirements of Underwriters Laboratories Standard 854 and is approved for installation in accordance with Article 230 of the NEC and has a rating of 600 volts.

 
06.06.2011
NM-B COPPER CONDUCTOR

Type NM-B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC). Type NM-B cable is commonly used for residential fixtures, switches, and loads rated for at least 90°C. Type NM-B ampacity limitation shall be in accordance with the 60°C conductor temperature rating, as specified in the National Electrical Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations. Type NM-B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness.

ARCHIVES