SOFT-DRAWN BARE CONDUCTORS
Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding.
SEE FULL PRODUCT SPECIFICATIONSBARREL PACKS SOFT-DRAWN BARE CONDUCTORS
Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding.
SEE FULL PRODUCT SPECIFICATIONSTHHN/MTW/THWN-2/T90 COPPER CONDUCTOR
Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applicatins. 0
SEE FULL PRODUCT SPECIFICATIONSBARREL PACKS THHN / MTW / THWN-2 / T90 COPPER CONDUCTOR
Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications.
SEE FULL PRODUCT SPECIFICATIONSTHHN/MTW/THWN-2/T90 COPPER CONDUCTOR SUPERSLICK ELITE®
Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications.
SEE FULL PRODUCT SPECIFICATIONSXHHW-2 / RW90 COPPER CONDUCTOR
Type XHHW-2/RW90 building wire is intended for general purpose applications utilized in conduit, underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the National Electrical Code (NEC).
SEE FULL PRODUCT SPECIFICATIONSBARREL PACKS XHHW-2 / RW90 COPPER CONDUCTOR
Type XHHW-2/RW90 building wire is intended for general purpose applications utilized in conduit, underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the National Electrical Code (NEC).
SEE FULL PRODUCT SPECIFICATIONSXHHW-2 / RW90 COPPER CONDUCTOR SUPERSLICK ELITE®
Type XHHW-2/RW90 building wire is intended for general purpose applications utilized in conduit, underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the National Electrical Code (NEC).
SEE FULL PRODUCT SPECIFICATIONSUSE-2/RHH/RHW-2 COPPER CONDUCTOR
Type USE-2 or RHH or RHW-2 copper conductors are suitable for use in conduit and raceways installed underground in conduit, wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90˚C.
SEE FULL PRODUCT SPECIFICATIONSPHOTOVOLTAIC COPPER CONDUCTOR 600V AND 1000V/2000V
Type Photovoltaic copper conductors are suitable for outdoor rooftop applications without conduit and for use in conduits and raceways installed underground in conduit in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90ºC.
SEE FULL PRODUCT SPECIFICATIONSTRACER WIRE COPPER CONDUCTOR / 30 VOLT & 600 VOLT
Listed for 30V or 600V. Primarily used in the detection of underground piping and other underground utility installations.
SEE FULL PRODUCT SPECIFICATIONSTHW-2 COPPER CONDUCTOR
Type THW-2 conductor is intended for general purpose applications utilized in conduit or other raceways for services, feeders, and branch-circuit wiring as specified in the National Electric Code (NEC). May be used in wet or dry locations at temperatures not to exceed 90˚C. Type THW-2 is permitted for 600 volt applications.
SEE FULL PRODUCT SPECIFICATIONSMTW / AWM / TEW MACHINE TOOL & APPLIANCE WIRE
Type MTW or TEW conductors are primarily used in control cabinets, in machine tool applications, and in appliance wiring applications at temperatures -25°C to 105°C. For use in accordance with the National Electrical Code (NEC) and NFPA Standard 79. Voltage rating for all applications is 600 volts.
SEE FULL PRODUCT SPECIFICATIONSTFFN / TFn / TEWN COPPER CONDUCTOR
Type TFFN (stranded) or TFN (solid) conductors are primarily used as fixture wire as defined by the National Electrical Code (NEC) at temperatures not to exceed 90°C in dry locations. For applications requiring Type MTW, the conductor is permitted for use in dry locations at 90°C or not to exceed 60°C in wet locations or where exposed to oils or coolants.
SEE FULL PRODUCT SPECIFICATIONSTW-#8 SOLID GREEN
Type TW is suitable for use in conduit or other recognized raceways for services, feeders, and branch-circuit wiring. Suitable for use in wet or dry locations where temperatures do not exceed 75°C.
SEE FULL PRODUCT SPECIFICATIONSBRAKE CABLE/RV ZIP CORD
Type TW is suitable for use in conduit or other recognized raceways for services, feeders, and branch-circuit wiring. Suitable for use in wet or dry locations where temperatures do not exceed 75°C.
SEE FULL PRODUCT SPECIFICATIONSMETAL-CLAD & ARMOR-CLAD CABLE/SMARTCOLOR ID ®
SMARTCOLOR ID® MC-COPPER CONDUCTOR-ALUMINUM ARMOR
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
SMARTCOLOR ID® MC-COPPER CONDUCTOR-STEEL ARMOR/THHN INNERS
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
SMARTCOLOR ID® MC-COPPER CONDUCTOR STEEL ARMOR/XHHW-2 INNERS
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
MC-SG (SMARTGROUNDTM) COPPER CONDUCTOR ALUMINUM ARMOR
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
MC-SG (SMARTGROUNDTM) COPPER CONDUCTOR STEEL ARMOR
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
MC HCF – SG (SMARTGROUNDTM) COPPER CONDUCTOR
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
MC-FPLP PLENUM RATED LIMITED POWER TYPE FIRE ALARM AND CONTROL CABLE
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
SMARTCOLOR ID® MC-COPPER CONDUCTOR ISOLATED GROUND ALUMINUM ARMOR THHN/THWN-2 INNERS
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
SMARTCOLOR ID® MC-COPPER CONDUCTOR OVERSIZED NEUTRAL AlUMINUM ARMOR THHN/THWN-2 INNERS
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
SMARTCOLOR ID® MC-COPPER CONDUCTOR MULTIPLE NEUTRAL ALUMINUM ARMOR THHN/THWN-2 INNERS
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
SMARTCOLOR ID® MC-COPPER CONDUCTOR-MULTIPLE NEUTRAL-STEEL ARMOR THHN/THWN-2 INNERS
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
SMARTCOLOR ID® MC-COPPER CONDUCTOR-MULTI-CIRCUIT-ALUMINUM ARMOR THHN/THWN-2 INNERS
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
MC-COPPER CONDUCTOR – ALUMINUM ARMOR PVC JACKET
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
MC-COPPER CONDUCTOR-Steel ARMOR PVC JACKET XHHW-2 INNERS
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
SMARTCOLOR ID® AC-COPPER CONDUCTOR-Aluminum Armor/THHN INNERS
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
SMARTCOLOR ID® AC-COPPER CONDUCTOR-STEEL ARMOR/THHN INNERS
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities
SMARTCOLOR ID® AC-HCF COPPER CONDUCTOR ALUMINUM ARMOR
- Suitable for applications requiring branch and feeder circuits for non-essential, general purposes electrical systems in patient care areas of health care facilities or for use in essential electrical systems when in accordance with 2008 NEC 517.30 (C)(3). Acceptable in facilities such as hospitals, nursing homes, dental offices, and other types of medical facilities including out patient facilities